Supply Dual-Port Exhaust Valve Stainless Steel Quick Exhaust Valve

Model NO.: Qb2X
Trademark: U-ideal
Specification: CE, SGS, ISO
Origin: China
HS Code: 84813000
Model NO.: Qb2X
Trademark: U-ideal
Specification: CE, SGS, ISO
Origin: China
HS Code: 84813000
Exhaust valve
Exhaust valve is applied to the independent heating system, central heating system, heating boiler furnace, central air conditioning, floor heating, solar heating system pipe exhaust, etc.Because usually have certain air dissolved in water, and air solubility with the rising of temperature decrease, so the water in the process of cycle gas gradually separated from the water, and gradually come together to form a big bubble column, even because there is water, so often have gases.
 
Technical Parameters:
1. Medium: clean water
2. Temperature: normal
3. Body material: gray cast iron
4. Float: 304 stainless steel
5. Test pressure: 1.5MPa
6. Operation pressure: 1.0MPa

Table size link

DN(mm)
D D1 D2 L H Z- Φ d
50 160 125 100 325 325 4-14
80 195 160 135 350 325 4-14
100 215 180 155 385 360 4-18
125 245 210 185 480 475 8-18
150 280 240 210 480 475 8-18
200 335 295 265 620 580 8-23


When have gas overflow system, the gas will be along the pipeline social climbers, and eventually gathered at the highest point of the system,Exhaust valve (In 19)
And exhaust valve is generally installed in the system, the highest point, when the gas into the vent valve cavity gathered in the upper portion of the exhaust valve, with the increasing of the gas inside the valve, pressure rise, when gas pressure is greater than the system pressure, the gas can make the cavity of the water drops, buoy with water level drops, open the vent;Gas, after the water level rise, buoy also rose, close the vent.Likewise, when negative pressure is formed in system, valve chamber in the water drops, vent open, because the outside atmospheric pressure is greater than the system pressure, so the atmosphere through the vent into the system, avoid the harm of negative pressure.Such as tighten exhaust valve cap on the valve body, stop exhaust exhaust valve, under normal circumstances, the bonnet should be in an open position.Exhaust valve can also be used with isolation valve, easy to the maintenance of exhaust valve.






Table of Air Discharge per Hour of Double-ported Exhaust Valve
 
 standard 50 75 100 150 200
m³ /h 6.5-13 6.5-13 10-20 19-38 31-62 
Exhaust valve
Exhaust valve is applied to the independent heating system, central heating system, heating boiler furnace, central air conditioning, floor heating, solar heating system pipe exhaust, etc.Because usually have certain air dissolved in water, and air solubility with the rising of temperature decrease, so the water in the process of cycle gas gradually separated from the water, and gradually come together to form a big bubble column, even because there is water, so often have gases.
 
Technical Parameters:
1. Medium: clean water
2. Temperature: normal
3. Body material: gray cast iron
4. Float: 304 stainless steel
5. Test pressure: 1.5MPa
6. Operation pressure: 1.0MPa

Table size link

DN(mm)
D D1 D2 L H Z- Φ d
50 160 125 100 325 325 4-14
80 195 160 135 350 325 4-14
100 215 180 155 385 360 4-18
125 245 210 185 480 475 8-18
150 280 240 210 480 475 8-18
200 335 295 265 620 580 8-23


When have gas overflow system, the gas will be along the pipeline social climbers, and eventually gathered at the highest point of the system,Exhaust valve (In 19)
And exhaust valve is generally installed in the system, the highest point, when the gas into the vent valve cavity gathered in the upper portion of the exhaust valve, with the increasing of the gas inside the valve, pressure rise, when gas pressure is greater than the system pressure, the gas can make the cavity of the water drops, buoy with water level drops, open the vent;Gas, after the water level rise, buoy also rose, close the vent.Likewise, when negative pressure is formed in system, valve chamber in the water drops, vent open, because the outside atmospheric pressure is greater than the system pressure, so the atmosphere through the vent into the system, avoid the harm of negative pressure.Such as tighten exhaust valve cap on the valve body, stop exhaust exhaust valve, under normal circumstances, the bonnet should be in an open position.Exhaust valve can also be used with isolation valve, easy to the maintenance of exhaust valve.






Table of Air Discharge per Hour of Double-ported Exhaust Valve
 
 standard 50 75 100 150 200
m³ /h 6.5-13 6.5-13 10-20 19-38 31-62 

Co2 laser engraving cutting machine for non-metal materials engraving cutting, such as acrylic, MDF, plywood, leather, fabric, stone, glass, foam...

Non-Metal Co2 Laser Engraving Cutting Machine

Non-metal Materials Co2 Laser Engraving Cutting Machine

Jinan Upgoal Mechanical Equipment Co.,Ltd , https://www.upgoalcutter.com

Posted on